TEL
81-78-335-7573
MENU
SEARCH

TSTA2

Overview
The TSTA2™ amplifier conditions incoming signals of the AT-100 AccuTorque™ sensor and sends them on to the SPECTRA™ electronic unit. In order to satisfy a variety of requirements, there are three AccuTorque™ sensor models available:

a single-channel torque sensor, a single-channel feed force sensor und a 2-channel torque and feed force sensor. Depending on the AccuTorque™ model chosen, critical process and tool status data will be available in real time. The non-contact transmission of data and energy by the AccuTorque™ sensor functions according to the rotor/stator principle, thus avoiding the use of batteries and ensuring trouble-free operations.

Excellent system reliability decreases maintenance costs and increases productivity.

Applications:
・determine tool status
・detect broken tools
・determine process status
・optimize processes
・ensure high quality production

Specs

Technical specifications
Dimensions (HxWxD in mm) 61 x 184 x 102
Weight approx. 880 g
Housing Aluminium
Protection class IP66
Temperature range Operation 0 bis 60 °C / Storage -40 bis 85 °C
Relative humidity 0 bis 95 % noncondensing
Mounting two M4 screws
Gain 1, 2, 4, 8
Gain error ± 2 %
Output signals 0 .. 10 V DC
Power requirements up to 250 mA @ +24 V DC
Sensor inputs 1
Sensor type AT100 AccuTorque, torgue, feed force
Voltage supply ± 24 V DC
Certification CE
Contact us

Amplifier